Difference between revisions of "Charge to digital converter (QDC)"

From LogicBox
Jump to: navigation, search
(Write register)
(Write register)
Line 69: Line 69:
 
|5
 
|5
 
|Clock control
 
|Clock control
|The ADC parallel data will be readout synchronized with the FPGA clock, in order to sample the data in the stable state the user can shift the clock phase in 256 steps from 0 to 10 ns.
+
|The ADC parallel data will be readout synchronized with the FPGA clock, in order to sample the data  
 +
in the stable state the user can shift the clock phase in 256 steps from 0 to 10 ns.
 
   '1' increments the clock phase in one step.
 
   '1' increments the clock phase in one step.
 
   '0' decrements the clock phase in one step.
 
   '0' decrements the clock phase in one step.

Revision as of 08:33, 25 February 2014

LogicPool (QDC)

This VHDL module needs a SU717 hardware sub-module to work.

Models

There is only one model for this module.

CBUS Address


Supported Hardware

SU7XX Just a link to the hardware module if any


Register Map

Module Address: 'Q' or Ox??

Read register

Read registers
Register Address Name Data
0 OUT_BUS Bit 7..0: Bus number that this module drives, through this bus the ADC value (raw or processed, see mode) can be saved in a LogicPool FIFO.
1 ADC(W) Bit 15..0: Register with the last ADC value (raw or processed, see mode)


Write register

Write registers
Register Address Name Data
0 IN_TRIGGER Bit 7..0: signal number to connect this module input. The module must be triggered to start an acquisition.
1 Gate(W) Bit 15..0: gate width in 10 ns steps. Integration time in 10 ns steps
2 Control 1 Bit 7..0: Start delay: sampling point after the trigger arrives and the integration time has been started.

Bit 16..14: Mode:

 “000” The difference between the start acquisition point and stop will be calculated. Data format is 15-Bit signed.
 “001” Only the stop point will be readout.
 “010” Only the start point will be readout.
 “011” The start and stop point will be readout.
 “100” All ADC values from start to stop will be readout. This mode is the best way to determinate the start and stop sample time.
4 Control 2 Bit 7..0: Stop Delay: sampling point after the integration time has been finished.
5 Clock control The ADC parallel data will be readout synchronized with the FPGA clock, in order to sample the data

in the stable state the user can shift the clock phase in 256 steps from 0 to 10 ns.

 '1' increments the clock phase in one step.
 '0' decrements the clock phase in one step.

Read/Write register

Read/Write registers
Register Address Name Data
0 MUX_IN Bit 7..0: multiplexer address
1 STATE_IN Bit 7..0: input value